Bourns Inc. |
GDT 600V 20% 5KA SURFACE MOUNT
- Voltage - DC Spark Over (Nom): 600V
- Impulse Discharge Current (8/20µs): 5000A (5kA)
- Tolerance: ±20%
- Number of Poles: 1
- Fail Short: No
- Mounting Type: Surface Mount
- Package / Case: 2-SMD
|
Package: 2-SMD |
Stock2,286 |
|
5000A (5kA) | ±20% | 1 | No | Surface Mount | 2-SMD |
|
|
Bourns Inc. |
GAS DISCHARGE TUBE
- Voltage - DC Spark Over (Nom): -
- Impulse Discharge Current (8/20µs): -
- Tolerance: -
- Number of Poles: -
- Fail Short: -
- Mounting Type: -
- Package / Case: -
|
Package: - |
Stock2,664 |
|
- | - | - | - | - | - |
|
|
Littelfuse Inc. |
GDT 150V 20KA T/H FAIL SHORT
- Voltage - DC Spark Over (Nom): 150V
- Impulse Discharge Current (8/20µs): 20000A (20kA)
- Tolerance: -
- Number of Poles: 3
- Fail Short: Yes
- Mounting Type: Through Hole
- Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
|
Package: Axial Cylinder, 3 Lead (Radial Bend) |
Stock8,694 |
|
20000A (20kA) | - | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Littelfuse Inc. |
GDT 150V 20% 10KA T/H FAIL SHORT
- Voltage - DC Spark Over (Nom): 150V
- Impulse Discharge Current (8/20µs): 10000A (10kA)
- Tolerance: ±20%
- Number of Poles: 3
- Fail Short: Yes
- Mounting Type: Through Hole
- Package / Case: Radial Cylinder, 3 Lead
|
Package: Radial Cylinder, 3 Lead |
Stock2,304 |
|
10000A (10kA) | ±20% | 3 | Yes | Through Hole | Radial Cylinder, 3 Lead |
|
|
Lumex Opto/Components Inc. |
GDT 400V 20% 2KA SURFACE MOUNT
- Voltage - DC Spark Over (Nom): 400V
- Impulse Discharge Current (8/20µs): 2000A (2kA)
- Tolerance: ±20%
- Number of Poles: 2
- Fail Short: No
- Mounting Type: Surface Mount
- Package / Case: 1812 (4532 Metric)
|
Package: 1812 (4532 Metric) |
Stock3,474 |
|
2000A (2kA) | ±20% | 2 | No | Surface Mount | 1812 (4532 Metric) |
|
|
Littelfuse Inc. |
GDT 350V 10KA
- Voltage - DC Spark Over (Nom): 350V
- Impulse Discharge Current (8/20µs): 10000A (10kA)
- Tolerance: -
- Number of Poles: 2
- Fail Short: No
- Mounting Type: User Defined
- Package / Case: Cylinder No Lead
|
Package: Cylinder No Lead |
Stock3,042 |
|
10000A (10kA) | - | 2 | No | User Defined | Cylinder No Lead |
|
|
Weidmuller |
GDT 150V 5KA DIN RAIL
- Voltage - DC Spark Over (Nom): 150V
- Impulse Discharge Current (8/20µs): 5000A (5kA)
- Tolerance: -
- Number of Poles: -
- Fail Short: -
- Mounting Type: DIN Rail
- Package / Case: Module
|
Package: Module |
Stock5,832 |
|
5000A (5kA) | - | - | - | DIN Rail | Module |
|
|
Eaton |
FUSE 690V 1P SPARKGAP DIN SPD RE
- Voltage - DC Spark Over (Nom): 690V
- Impulse Discharge Current (8/20µs): 25000A (25kA)
- Tolerance: -
- Number of Poles: 1
- Fail Short: No
- Mounting Type: DIN Rail
- Package / Case: Module
|
Package: Module |
Stock7,398 |
|
25000A (25kA) | - | 1 | No | DIN Rail | Module |
|
|
Bourns Inc. |
GDT 2200V 20% 20KA THROUGH HOLE
- Voltage - DC Spark Over (Nom): 2200V
- Impulse Discharge Current (8/20µs): 20000A (20kA)
- Tolerance: ±20%
- Number of Poles: 2
- Fail Short: No
- Mounting Type: Through Hole
- Package / Case: Axial Cylinder
|
Package: Axial Cylinder |
Stock7,020 |
|
20000A (20kA) | ±20% | 2 | No | Through Hole | Axial Cylinder |
|
|
Littelfuse Inc. |
GDT 230V 5KA THROUGH HOLE
- Voltage - DC Spark Over (Nom): 230V
- Impulse Discharge Current (8/20µs): 5000A (5kA)
- Tolerance: -
- Number of Poles: 2
- Fail Short: No
- Mounting Type: Through Hole
- Package / Case: Axial Cylinder
|
Package: Axial Cylinder |
Stock6,696 |
|
5000A (5kA) | - | 2 | No | Through Hole | Axial Cylinder |
|
|
Littelfuse Inc. |
GDT 350V 5KA THROUGH HOLE
- Voltage - DC Spark Over (Nom): 350V
- Impulse Discharge Current (8/20µs): 5000A (5kA)
- Tolerance: -
- Number of Poles: 2
- Fail Short: No
- Mounting Type: Through Hole
- Package / Case: Axial Cylinder
|
Package: Axial Cylinder |
Stock5,004 |
|
5000A (5kA) | - | 2 | No | Through Hole | Axial Cylinder |
|
|
Littelfuse Inc. |
GDT 600V 5KA THROUGH HOLE
- Voltage - DC Spark Over (Nom): 600V
- Impulse Discharge Current (8/20µs): 5000A (5kA)
- Tolerance: -
- Number of Poles: 2
- Fail Short: No
- Mounting Type: Through Hole
- Package / Case: Axial Cylinder, Radial Bend
|
Package: Axial Cylinder, Radial Bend |
Stock3,006 |
|
5000A (5kA) | - | 2 | No | Through Hole | Axial Cylinder, Radial Bend |
|
|
Littelfuse Inc. |
GDT 170V 5KA SMD FAIL SHORT
- Voltage - DC Spark Over (Nom): 170V
- Impulse Discharge Current (8/20µs): 5000A (5kA)
- Tolerance: -
- Number of Poles: 3
- Fail Short: Yes
- Mounting Type: Surface Mount
- Package / Case: 3-SMD Cylinder Square End
|
Package: 3-SMD Cylinder Square End |
Stock5,238 |
|
5000A (5kA) | - | 3 | Yes | Surface Mount | 3-SMD Cylinder Square End |
|
|
Bourns Inc. |
GDT 90V 20% 20KA THROUGH HOLE
- Voltage - DC Spark Over (Nom): 90V
- Impulse Discharge Current (8/20µs): 20000A (20kA)
- Tolerance: ±20%
- Number of Poles: 3
- Fail Short: No
- Mounting Type: Through Hole
- Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
|
Package: Axial Cylinder, 3 Lead (Radial Bend) |
Stock2,646 |
|
20000A (20kA) | ±20% | 3 | No | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns Inc. |
GDT 200V 20% 10KA SURFACE MOUNT
- Voltage - DC Spark Over (Nom): 200V
- Impulse Discharge Current (8/20µs): 10000A (10kA)
- Tolerance: ±20%
- Number of Poles: 3
- Fail Short: No
- Mounting Type: Surface Mount
- Package / Case: 3-SMD Cylinder Square End
|
Package: 3-SMD Cylinder Square End |
Stock5,004 |
|
10000A (10kA) | ±20% | 3 | No | Surface Mount | 3-SMD Cylinder Square End |
|
|
Lumex Opto/Components Inc. |
GDT 200V 20% 2KA SURFACE MOUNT
- Voltage - DC Spark Over (Nom): 200V
- Impulse Discharge Current (8/20µs): 2000A (2kA)
- Tolerance: ±20%
- Number of Poles: 2
- Fail Short: No
- Mounting Type: Surface Mount
- Package / Case: 1812 (4532 Metric)
|
Package: 1812 (4532 Metric) |
Stock6,642 |
|
2000A (2kA) | ±20% | 2 | No | Surface Mount | 1812 (4532 Metric) |
|
|
Bourns Inc. |
GDT 150V 15% 10KA THROUGH HOLE
- Voltage - DC Spark Over (Nom): 150V
- Impulse Discharge Current (8/20µs): 10000A (10kA)
- Tolerance: ±15%
- Number of Poles: 2
- Fail Short: No
- Mounting Type: Through Hole
- Package / Case: Axial Cylinder
|
Package: Axial Cylinder |
Stock7,452 |
|
10000A (10kA) | ±15% | 2 | No | Through Hole | Axial Cylinder |
|
|
Bourns Inc. |
GDT 150V 15% 10KA THROUGH HOLE
- Voltage - DC Spark Over (Nom): 150V
- Impulse Discharge Current (8/20µs): 10000A (10kA)
- Tolerance: ±15%
- Number of Poles: 2
- Fail Short: No
- Mounting Type: Through Hole
- Package / Case: Axial Cylinder
|
Package: Axial Cylinder |
Stock6,858 |
|
10000A (10kA) | ±15% | 2 | No | Through Hole | Axial Cylinder |
|
|
Bourns Inc. |
GDT 420V 15% 5KA THROUGH HOLE
- Voltage - DC Spark Over (Nom): 420V
- Impulse Discharge Current (8/20µs): 5000A (5kA)
- Tolerance: ±15%
- Number of Poles: 2
- Fail Short: No
- Mounting Type: Through Hole
- Package / Case: Axial Cylinder
|
Package: Axial Cylinder |
Stock7,380 |
|
5000A (5kA) | ±15% | 2 | No | Through Hole | Axial Cylinder |
|
|
Bourns Inc. |
GDT 400V 15% 5KA SURFACE MOUNT
- Voltage - DC Spark Over (Nom): 400V
- Impulse Discharge Current (8/20µs): 5000A (5kA)
- Tolerance: ±15%
- Number of Poles: 2
- Fail Short: No
- Mounting Type: Surface Mount
- Package / Case: 2-SMD Cylinder Square End
|
Package: 2-SMD Cylinder Square End |
Stock4,572 |
|
5000A (5kA) | ±15% | 2 | No | Surface Mount | 2-SMD Cylinder Square End |
|
|
Littelfuse Inc. |
GDT 420V 20% 10KA THROUGH HOLE
- Voltage - DC Spark Over (Nom): 420V
- Impulse Discharge Current (8/20µs): 10000A (10kA)
- Tolerance: ±20%
- Number of Poles: 3
- Fail Short: No
- Mounting Type: Through Hole
- Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
|
Package: Axial Cylinder, 3 Lead (Radial Bend) |
Stock12,066 |
|
10000A (10kA) | ±20% | 3 | No | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns Inc. |
GDT 350V 15% 10KA THROUGH HOLE
- Voltage - DC Spark Over (Nom): 350V
- Impulse Discharge Current (8/20µs): 10000A (10kA)
- Tolerance: ±15%
- Number of Poles: 2
- Fail Short: No
- Mounting Type: Through Hole
- Package / Case: Axial Cylinder
|
Package: Axial Cylinder |
Stock18,300 |
|
10000A (10kA) | ±15% | 2 | No | Through Hole | Axial Cylinder |
|
|
Littelfuse Inc. |
GDT 275V 20KA HOLDER
- Voltage - DC Spark Over (Nom): 275V
- Impulse Discharge Current (8/20µs): 20000A (20kA)
- Tolerance: -
- Number of Poles: 3
- Fail Short: No
- Mounting Type: Holder
- Package / Case: Cartridge
|
Package: Cartridge |
Stock8,118 |
|
20000A (20kA) | - | 3 | No | Holder | Cartridge |
|
|
Bourns Inc. |
GDT 600V 15% 10KA THROUGH HOLE
- Voltage - DC Spark Over (Nom): 600V
- Impulse Discharge Current (8/20µs): 10000A (10kA)
- Tolerance: ±15%
- Number of Poles: 2
- Fail Short: No
- Mounting Type: Through Hole
- Package / Case: Axial Cylinder
|
Package: Axial Cylinder |
Stock19,644 |
|
10000A (10kA) | ±15% | 2 | No | Through Hole | Axial Cylinder |
|
|
Littelfuse Inc. |
GDT 470V 20% 10KA SURFACE MOUNT
- Voltage - DC Spark Over (Nom): 470V
- Impulse Discharge Current (8/20µs): 10000A (10kA)
- Tolerance: ±20%
- Number of Poles: 2
- Fail Short: No
- Mounting Type: Surface Mount
- Package / Case: 2-SMD Cylinder Square End
|
Package: 2-SMD Cylinder Square End |
Stock20,286 |
|
10000A (10kA) | ±20% | 2 | No | Surface Mount | 2-SMD Cylinder Square End |
|
|
Littelfuse Inc. |
GDT 470V 3KA SURFACE MOUNT
- Voltage - DC Spark Over (Nom): 470V
- Impulse Discharge Current (8/20µs): 3000A (3kA)
- Tolerance: -
- Number of Poles: 2
- Fail Short: No
- Mounting Type: Surface Mount
- Package / Case: 2-SMD Cylinder Square End
|
Package: 2-SMD Cylinder Square End |
Stock2,538 |
|
3000A (3kA) | - | 2 | No | Surface Mount | 2-SMD Cylinder Square End |
|
|
EPCOS (TDK) |
GDT 800V 15% 10KA
- Voltage - DC Spark Over (Nom): 800V
- Impulse Discharge Current (8/20µs): 10000A (10kA)
- Tolerance: ±15%
- Number of Poles: 2
- Fail Short: No
- Mounting Type: User Defined
- Package / Case: Cylinder No Lead
|
Package: Cylinder No Lead |
Stock8,148 |
|
10000A (10kA) | ±15% | 2 | No | User Defined | Cylinder No Lead |
|
|
EPCOS (TDK) |
GDT 90V 20% 20KA THROUGH HOLE
- Voltage - DC Spark Over (Nom): 90V
- Impulse Discharge Current (8/20µs): 20000A (20kA)
- Tolerance: ±20%
- Number of Poles: 2
- Fail Short: No
- Mounting Type: Through Hole
- Package / Case: Axial Cylinder
|
Package: Axial Cylinder |
Stock28,692 |
|
20000A (20kA) | ±20% | 2 | No | Through Hole | Axial Cylinder |