Phoenix Contact |
SENSOR CURRENT HALL 55A AC/DC
- For Measuring: AC/DC
- Sensor Type: Hall Effect, Open Loop
- Current - Sensing: 55A
- Number of Channels: 1
- Output: Ratiometric, Voltage and Current
- Sensitivity: -
- Frequency: 15Hz ~ 400Hz
- Linearity: -
- Accuracy: ±0.5%
- Voltage - Supply: 20 V ~ 30 V
- Response Time: 330ms (AC), 40ms (DC)
- Current - Supply (Max): 50mA
- Operating Temperature: -20°C ~ 60°C
- Polarization: Bidirectional
- Mounting Type: DIN Rail
- Package / Case: Module
|
Package: Module |
Stock5,508 |
|
Hall Effect, Open Loop | 55A | 1 | Ratiometric, Voltage and Current | - | 15Hz ~ 400Hz | - | ±0.5% | 20 V ~ 30 V | 330ms (AC), 40ms (DC) | 50mA | -20°C ~ 60°C | Bidirectional | DIN Rail | Module |
|
|
Phoenix Contact |
SENSOR CURRENT HALL 11A AC/DC
- For Measuring: AC/DC
- Sensor Type: Hall Effect, Open Loop
- Current - Sensing: 11A
- Number of Channels: 1
- Output: Ratiometric, Voltage and Current
- Sensitivity: -
- Frequency: 15Hz ~ 400Hz
- Linearity: -
- Accuracy: ±0.5%
- Voltage - Supply: 20 V ~ 30 V
- Response Time: 330ms (AC), 40ms (DC)
- Current - Supply (Max): 50mA
- Operating Temperature: -20°C ~ 60°C
- Polarization: Bidirectional
- Mounting Type: DIN Rail
- Package / Case: Module
|
Package: Module |
Stock7,290 |
|
Hall Effect, Open Loop | 11A | 1 | Ratiometric, Voltage and Current | - | 15Hz ~ 400Hz | - | ±0.5% | 20 V ~ 30 V | 330ms (AC), 40ms (DC) | 50mA | -20°C ~ 60°C | Bidirectional | DIN Rail | Module |
|
|
Phoenix Contact |
SENSOR CURRENT HALL 55A AC/DC
- For Measuring: AC/DC
- Sensor Type: Hall Effect, Open Loop
- Current - Sensing: 55A
- Number of Channels: 1
- Output: Ratiometric, Voltage and Current
- Sensitivity: -
- Frequency: 15Hz ~ 400Hz
- Linearity: -
- Accuracy: ±0.5%
- Voltage - Supply: 20 V ~ 30 V
- Response Time: 330ms (AC), 40ms (DC)
- Current - Supply (Max): 40mA
- Operating Temperature: -20°C ~ 60°C
- Polarization: Bidirectional
- Mounting Type: DIN Rail
- Package / Case: Module
|
Package: Module |
Stock2,826 |
|
Hall Effect, Open Loop | 55A | 1 | Ratiometric, Voltage and Current | - | 15Hz ~ 400Hz | - | ±0.5% | 20 V ~ 30 V | 330ms (AC), 40ms (DC) | 40mA | -20°C ~ 60°C | Bidirectional | DIN Rail | Module |
|
|
Phoenix Contact |
SENSOR CURRENT HALL 11A AC/DC
- For Measuring: AC/DC
- Sensor Type: Hall Effect, Open Loop
- Current - Sensing: 11A
- Number of Channels: 1
- Output: Ratiometric, Voltage and Current
- Sensitivity: -
- Frequency: 15Hz ~ 400Hz
- Linearity: -
- Accuracy: ±0.5%
- Voltage - Supply: 20 V ~ 30 V
- Response Time: 330ms (AC), 40ms (DC)
- Current - Supply (Max): 40mA
- Operating Temperature: -20°C ~ 60°C
- Polarization: Bidirectional
- Mounting Type: DIN Rail
- Package / Case: Module
|
Package: Module |
Stock5,958 |
|
Hall Effect, Open Loop | 11A | 1 | Ratiometric, Voltage and Current | - | 15Hz ~ 400Hz | - | ±0.5% | 20 V ~ 30 V | 330ms (AC), 40ms (DC) | 40mA | -20°C ~ 60°C | Bidirectional | DIN Rail | Module |
|
|
Phoenix Contact |
PACT RCP-4000A-1A
- For Measuring: -
- Sensor Type: -
- Current - Sensing: -
- Number of Channels: -
- Output: -
- Sensitivity: -
- Frequency: -
- Linearity: -
- Accuracy: -
- Voltage - Supply: -
- Response Time: -
- Current - Supply (Max): -
- Operating Temperature: -
- Polarization: -
- Mounting Type: -
- Package / Case: -
|
Package: - |
Stock3,834 |
|
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
|
Phoenix Contact |
PACT RCP-D95
- For Measuring: AC
- Sensor Type: Transformer w/Conditioning
- Current - Sensing: -
- Number of Channels: 1
- Output: Ratiometric, Voltage
- Sensitivity: -
- Frequency: 40Hz ~ 20kHz
- Linearity: ±0.1%
- Accuracy: ±0.2%
- Voltage - Supply: -
- Response Time: -
- Current - Supply (Max): -
- Operating Temperature: -30°C ~ 80°C
- Polarization: Bidirectional
- Mounting Type: Screw
- Package / Case: Module
|
Package: Module |
Stock8,982 |
|
Transformer w/Conditioning | - | 1 | Ratiometric, Voltage | - | 40Hz ~ 20kHz | ±0.1% | ±0.2% | - | - | - | -30°C ~ 80°C | Bidirectional | Screw | Module |
|
|
Phoenix Contact |
PACT RCP-D190
- For Measuring: AC
- Sensor Type: Transformer w/Conditioning
- Current - Sensing: -
- Number of Channels: 1
- Output: Ratiometric, Voltage
- Sensitivity: -
- Frequency: 40Hz ~ 20kHz
- Linearity: ±0.1%
- Accuracy: ±0.2%
- Voltage - Supply: -
- Response Time: -
- Current - Supply (Max): -
- Operating Temperature: -30°C ~ 80°C
- Polarization: Bidirectional
- Mounting Type: Screw
- Package / Case: Module
|
Package: Module |
Stock3,276 |
|
Transformer w/Conditioning | - | 1 | Ratiometric, Voltage | - | 40Hz ~ 20kHz | ±0.1% | ±0.2% | - | - | - | -30°C ~ 80°C | Bidirectional | Screw | Module |
|
|
Phoenix Contact |
PACT RCP-D140
- For Measuring: AC
- Sensor Type: Transformer w/Conditioning
- Current - Sensing: -
- Number of Channels: 1
- Output: Ratiometric, Voltage
- Sensitivity: -
- Frequency: 40Hz ~ 20kHz
- Linearity: ±0.1%
- Accuracy: ±0.2%
- Voltage - Supply: -
- Response Time: -
- Current - Supply (Max): -
- Operating Temperature: -30°C ~ 80°C
- Polarization: Bidirectional
- Mounting Type: Screw
- Package / Case: Module
|
Package: Module |
Stock8,802 |
|
Transformer w/Conditioning | - | 1 | Ratiometric, Voltage | - | 40Hz ~ 20kHz | ±0.1% | ±0.2% | - | - | - | -30°C ~ 80°C | Bidirectional | Screw | Module |
|
|
Phoenix Contact |
CURRENT MEASURING TRANSDUCER
- For Measuring: AC
- Sensor Type: Transformer w/Conditioning
- Current - Sensing: 1A, 5A (Selectable)
- Number of Channels: 1
- Output: Ratiometric, 0 V ~ 10 V, 0 ~ 20mA
- Sensitivity: -
- Frequency: 45Hz ~ 60Hz
- Linearity: -
- Accuracy: -
- Voltage - Supply: -
- Response Time: -
- Current - Supply (Max): -
- Operating Temperature: -25°C ~ 65°C
- Polarization: Bidirectional
- Mounting Type: DIN Rail
- Package / Case: Module
|
Package: Module |
Stock6,786 |
|
Transformer w/Conditioning | 1A, 5A (Selectable) | 1 | Ratiometric, 0 V ~ 10 V, 0 ~ 20mA | - | 45Hz ~ 60Hz | - | - | - | - | - | -25°C ~ 65°C | Bidirectional | DIN Rail | Module |
|
|
Phoenix Contact |
PACT RCP-4000A-1A-D190
- For Measuring: AC
- Sensor Type: Transformer w/Conditioning
- Current - Sensing: 100A ~ 4000A (Selectable)
- Number of Channels: 1
- Output: Ratiometric, Voltage
- Sensitivity: -
- Frequency: 10Hz ~ 5kHz
- Linearity: ±0.5%
- Accuracy: ±1%
- Voltage - Supply: 24V
- Response Time: -
- Current - Supply (Max): -
- Operating Temperature: 20°C ~ 70°C
- Polarization: Bidirectional
- Mounting Type: DIN Rail
- Package / Case: Module
|
Package: Module |
Stock4,806 |
|
Transformer w/Conditioning | 100A ~ 4000A (Selectable) | 1 | Ratiometric, Voltage | - | 10Hz ~ 5kHz | ±0.5% | ±1% | 24V | - | - | 20°C ~ 70°C | Bidirectional | DIN Rail | Module |
|
|
Phoenix Contact |
PACT RCP-4000A-1A-D140
- For Measuring: AC
- Sensor Type: Transformer w/Conditioning
- Current - Sensing: 100A ~ 4000A (Selectable)
- Number of Channels: 1
- Output: Ratiometric, Voltage
- Sensitivity: -
- Frequency: 10Hz ~ 5kHz
- Linearity: ±0.5%
- Accuracy: ±1%
- Voltage - Supply: 24V
- Response Time: -
- Current - Supply (Max): -
- Operating Temperature: 20°C ~ 70°C
- Polarization: Bidirectional
- Mounting Type: DIN Rail
- Package / Case: Module
|
Package: Module |
Stock3,906 |
|
Transformer w/Conditioning | 100A ~ 4000A (Selectable) | 1 | Ratiometric, Voltage | - | 10Hz ~ 5kHz | ±0.5% | ±1% | 24V | - | - | 20°C ~ 70°C | Bidirectional | DIN Rail | Module |
|
|
Phoenix Contact |
SENSOR CURRENT HALL 55A AC/DC
- For Measuring: AC/DC
- Sensor Type: Hall Effect, Open Loop
- Current - Sensing: 55A
- Number of Channels: 1
- Output: Ratiometric, Voltage and Current
- Sensitivity: -
- Frequency: 15Hz ~ 400Hz
- Linearity: -
- Accuracy: ±0.5%
- Voltage - Supply: 20 V ~ 30 V
- Response Time: 330ms (AC), 40ms (DC)
- Current - Supply (Max): 50mA
- Operating Temperature: -20°C ~ 60°C
- Polarization: Bidirectional
- Mounting Type: DIN Rail
- Package / Case: Module
|
Package: Module |
Stock8,154 |
|
Hall Effect, Open Loop | 55A | 1 | Ratiometric, Voltage and Current | - | 15Hz ~ 400Hz | - | ±0.5% | 20 V ~ 30 V | 330ms (AC), 40ms (DC) | 50mA | -20°C ~ 60°C | Bidirectional | DIN Rail | Module |
|
|
Phoenix Contact |
PACT RCP-4000A-1A-D95
- For Measuring: AC
- Sensor Type: Transformer w/Conditioning
- Current - Sensing: 100A ~ 4000A (Selectable)
- Number of Channels: 1
- Output: Ratiometric, Voltage
- Sensitivity: -
- Frequency: 10Hz ~ 5kHz
- Linearity: ±0.5%
- Accuracy: ±1%
- Voltage - Supply: 24V
- Response Time: -
- Current - Supply (Max): -
- Operating Temperature: 20°C ~ 70°C
- Polarization: Bidirectional
- Mounting Type: DIN Rail
- Package / Case: Module
|
Package: Module |
Stock7,470 |
|
Transformer w/Conditioning | 100A ~ 4000A (Selectable) | 1 | Ratiometric, Voltage | - | 10Hz ~ 5kHz | ±0.5% | ±1% | 24V | - | - | 20°C ~ 70°C | Bidirectional | DIN Rail | Module |