Omron Automation and Safety |
SAFETY LIGHT CURTAIN SYSTEM
- Sensing Method: Through-Beam
- Sensing Distance: 787.4" (20m)
- Voltage - Supply: 24V
- Response Time: 14ms
- Output Configuration: PNP - Open Collector
- Connection Method: Cable with Connector
- Ingress Protection: IP65
- Cable Length: -
- Light Source: Infrared (880nm)
- Adjustment Type: -
- Operating Temperature: -10°C ~ 55°C
|
Package: - |
Stock8,226 |
|
787.4" (20m) | 24V | 14ms | PNP - Open Collector | Cable with Connector | IP65 | - | Infrared (880nm) | - | -10°C ~ 55°C |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN SYSTEM
- Sensing Method: Through-Beam
- Sensing Distance: 787.4" (20m)
- Voltage - Supply: 24V
- Response Time: 14ms
- Output Configuration: PNP - Open Collector
- Connection Method: Cable with Connector
- Ingress Protection: IP65
- Cable Length: -
- Light Source: Infrared (880nm)
- Adjustment Type: -
- Operating Temperature: -10°C ~ 55°C
|
Package: - |
Stock8,208 |
|
787.4" (20m) | 24V | 14ms | PNP - Open Collector | Cable with Connector | IP65 | - | Infrared (880nm) | - | -10°C ~ 55°C |
|
|
Omron Automation and Safety |
SPARE RECEIVER
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock2,934 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SPARE RECEIVER
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock6,642 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock8,388 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock3,708 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock7,542 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock6,318 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock5,616 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
FG IP67 COVER MS46-1570 SINGLE
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock5,490 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
PHOTOMICRO SENSOR
- Sensing Method: Reflective, Convergent
- Sensing Distance: 0.394" ~ 2.362" (10mm ~ 60mm) ADJ
- Voltage - Supply: 12 V ~ 24 V
- Response Time: 1ms
- Output Configuration: PNP - Dark-ON/Light-ON - Selectable
- Connection Method: Wire
- Ingress Protection: IEC IP40
- Cable Length: -
- Light Source: Infrared (660nm)
- Adjustment Type: Adjustable
- Operating Temperature: -25°C ~ 55°C
|
Package: - |
Stock4,554 |
|
0.394" ~ 2.362" (10mm ~ 60mm) ADJ | 12 V ~ 24 V | 1ms | PNP - Dark-ON/Light-ON - Selectable | Wire | IEC IP40 | - | Infrared (660nm) | Adjustable | -25°C ~ 55°C |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock2,448 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock5,220 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock8,658 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock2,736 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock7,902 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock5,292 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock5,220 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock2,664 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
F3SJ-A1320P30
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock2,376 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock6,822 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Panasonic Industrial Automation Sales |
LIGHT CURTAIN HAND 1910MM
- Sensing Method: -
- Sensing Distance: 11.811" ~ 275.59" (300mm ~ 7m)
- Voltage - Supply: 24V
- Response Time: 14ms
- Output Configuration: NPN/PNP
- Connection Method: Connector
- Ingress Protection: IP65/67 - Dust Tight, Water Resistant, Waterproof
- Cable Length: -
- Light Source: Infrared
- Adjustment Type: -
- Operating Temperature: -10°C ~ 55°C
|
Package: - |
Stock7,002 |
|
11.811" ~ 275.59" (300mm ~ 7m) | 24V | 14ms | NPN/PNP | Connector | IP65/67 - Dust Tight, Water Resistant, Waterproof | - | Infrared | - | -10°C ~ 55°C |
|
|
Omron Automation and Safety |
MC47 WELD SHIELD 1425MM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock4,230 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
THRU-BEAM 0.8M NPN TR M8 CONN
- Sensing Method: Transmissive
- Sensing Distance: 31.496" (800mm)
- Voltage - Supply: 10 V ~ 30 V
- Response Time: 1ms
- Output Configuration: NPN - Open Collector/Light-ON
- Connection Method: Connector
- Ingress Protection: IEC IP67, IP69K
- Cable Length: -
- Light Source: Infrared (870nm)
- Adjustment Type: Single-Turn
- Operating Temperature: -25°C ~ 55°C
|
Package: - |
Stock3,924 |
|
31.496" (800mm) | 10 V ~ 30 V | 1ms | NPN - Open Collector/Light-ON | Connector | IEC IP67, IP69K | - | Infrared (870nm) | Single-Turn | -25°C ~ 55°C |
|
|
Omron Automation and Safety |
SENSOR PHOTOELECTRIC 10-100MM
- Sensing Method: Retroreflective
- Sensing Distance: 0.394" ~ 3.937" (10mm ~ 100mm) ADJ
- Voltage - Supply: 10 V ~ 30 V
- Response Time: 1ms
- Output Configuration: NPN - Dark-ON/Light-ON - Selectable
- Connection Method: Cable
- Ingress Protection: IEC IP67, IP69K
- Cable Length: -
- Light Source: Infrared (650nm)
- Adjustment Type: -
- Operating Temperature: -25°C ~ 55°C
|
Package: - |
Stock2,880 |
|
0.394" ~ 3.937" (10mm ~ 100mm) ADJ | 10 V ~ 30 V | 1ms | NPN - Dark-ON/Light-ON - Selectable | Cable | IEC IP67, IP69K | - | Infrared (650nm) | - | -25°C ~ 55°C |
|
|
Panasonic Industrial Automation Sales |
SENSOR PHOTO 0.1-2M 12-24VDC PNP
- Sensing Method: Retroreflective
- Sensing Distance: 78.7" (200cm) 6.6'
- Voltage - Supply: 12 V ~ 24 V
- Response Time: 1ms
- Output Configuration: PNP - Open Collector
- Connection Method: Connector, M12
- Ingress Protection: IP67
- Cable Length: -
- Light Source: Infrared
- Adjustment Type: -
- Operating Temperature: -25°C ~ 55°C
|
Package: - |
Stock3,852 |
|
78.7" (200cm) 6.6' | 12 V ~ 24 V | 1ms | PNP - Open Collector | Connector, M12 | IP67 | - | Infrared | - | -25°C ~ 55°C |
|
|
Panasonic Industrial Automation Sales |
SENSOR THRUBM 200MM LT ON NPN OU
- Sensing Method: Through-Beam
- Sensing Distance: 7.874" (200mm)
- Voltage - Supply: 12 V ~ 24 V
- Response Time: 500µs
- Output Configuration: NPN - Open Collector/Light-ON
- Connection Method: Cable
- Ingress Protection: IP67
- Cable Length: 80.0" (200cm)
- Light Source: Red LED
- Adjustment Type: Fixed
- Operating Temperature: -10°C ~ 55°C
|
Package: - |
Stock7,452 |
|
7.874" (200mm) | 12 V ~ 24 V | 500µs | NPN - Open Collector/Light-ON | Cable | IP67 | 80.0" (200cm) | Red LED | Fixed | -10°C ~ 55°C |
|
|
Omron Automation and Safety |
PHOTO REC/TRANS/1M DIST/ LT ON
- Sensing Method: Through-Beam
- Sensing Distance: 39.370" (1m)
- Voltage - Supply: 5 V ~ 24 V
- Response Time: 1ms
- Output Configuration: NPN - Open Collector/Light-ON
- Connection Method: Connector
- Ingress Protection: IEC IP60
- Cable Length: -
- Light Source: Infrared (940nm)
- Adjustment Type: Adjustable
- Operating Temperature: -10°C ~ 55°C
|
Package: - |
Stock6,264 |
|
39.370" (1m) | 5 V ~ 24 V | 1ms | NPN - Open Collector/Light-ON | Connector | IEC IP60 | - | Infrared (940nm) | Adjustable | -10°C ~ 55°C |