Omron Automation and Safety |
SPARE RECEIVER
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock4,968 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SPARE TRANSMITTER
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock3,978 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock7,362 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock5,634 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock3,402 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock5,868 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock2,124 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock2,268 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SENS OPTO REFL 35MM PREWIRED MOD
- Sensing Method: Reflective, Diffuse
- Sensing Distance: 1.378" (35mm)
- Voltage - Supply: 12 V ~ 24 V
- Response Time: 5ms
- Output Configuration: NPN - Dark-ON/Light-ON - Selectable
- Connection Method: Wire
- Ingress Protection: IEC IP67
- Cable Length: -
- Light Source: Green (565nm)
- Adjustment Type: Single-Turn
- Operating Temperature: -25°C ~ 55°C
|
Package: - |
Stock4,752 |
|
1.378" (35mm) | 12 V ~ 24 V | 5ms | NPN - Dark-ON/Light-ON - Selectable | Wire | IEC IP67 | - | Green (565nm) | Single-Turn | -25°C ~ 55°C |
|
|
Omron Automation and Safety |
LIGHT SOURCE ONLY
- Sensing Method: Through-Beam
- Sensing Distance: 196.850" (5m)
- Voltage - Supply: 12 V ~ 24 V
- Response Time: 3ms
- Output Configuration: NPN - Dark-ON/Light-ON - Selectable
- Connection Method: Cable
- Ingress Protection: NEMA 1, 3, 4X, 6, 12; IEC 144 IP67
- Cable Length: -
- Light Source: Infrared
- Adjustment Type: -
- Operating Temperature: -25°C ~ 55°C
|
Package: - |
Stock6,714 |
|
196.850" (5m) | 12 V ~ 24 V | 3ms | NPN - Dark-ON/Light-ON - Selectable | Cable | NEMA 1, 3, 4X, 6, 12; IEC 144 IP67 | - | Infrared | - | -25°C ~ 55°C |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock8,982 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock6,498 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock6,246 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock5,202 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock4,590 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: Through-Beam
- Sensing Distance: 787.4" (20m)
- Voltage - Supply: 24V
- Response Time: 14ms
- Output Configuration: PNP - Open Collector
- Connection Method: Cable with Connector
- Ingress Protection: IP65
- Cable Length: -
- Light Source: Infrared (880nm)
- Adjustment Type: -
- Operating Temperature: -10°C ~ 55°C
|
Package: - |
Stock3,508 |
|
787.4" (20m) | 24V | 14ms | PNP - Open Collector | Cable with Connector | IP65 | - | Infrared (880nm) | - | -10°C ~ 55°C |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock5,562 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: Through-Beam
- Sensing Distance: 787.4" (20m)
- Voltage - Supply: 24V
- Response Time: 14ms
- Output Configuration: PNP - Open Collector
- Connection Method: Cable with Connector
- Ingress Protection: IP65
- Cable Length: -
- Light Source: Infrared (880nm)
- Adjustment Type: -
- Operating Temperature: -10°C ~ 55°C
|
Package: - |
Stock7,002 |
|
787.4" (20m) | 24V | 14ms | PNP - Open Collector | Cable with Connector | IP65 | - | Infrared (880nm) | - | -10°C ~ 55°C |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock8,046 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock4,626 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock5,490 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
F3SJ-A0780P25-TS
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock2,502 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock7,110 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SPARE TRANSMITTER
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock3,436 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SENS OPTO REFL 50MM-250MM PREWIR
- Sensing Method: Reflective
- Sensing Distance: 1.969" ~ 9.843" (50mm ~ 250mm) ADJ
- Voltage - Supply: 12 V ~ 24 V
- Response Time: 1ms
- Output Configuration: NPN - Dark-ON/Light-ON - Selectable
- Connection Method: Wire
- Ingress Protection: NEMA 1, 3, 4X, 6, 12; IEC 144 IP67
- Cable Length: -
- Light Source: Infrared
- Adjustment Type: Adjustable
- Operating Temperature: -25°C ~ 55°C
|
Package: - |
Stock5,328 |
|
1.969" ~ 9.843" (50mm ~ 250mm) ADJ | 12 V ~ 24 V | 1ms | NPN - Dark-ON/Light-ON - Selectable | Wire | NEMA 1, 3, 4X, 6, 12; IEC 144 IP67 | - | Infrared | Adjustable | -25°C ~ 55°C |
|
|
Omron Automation and Safety |
OPTO SENSOR FIBER OPTIC 50CM
- Sensing Method: Through-Beam
- Sensing Distance: 19.685" (500mm)
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: Cable
- Ingress Protection: IEC IP64
- Cable Length: -
- Light Source: Infrared (950nm)
- Adjustment Type: -
- Operating Temperature: -25°C ~ 70°C
|
Package: - |
Stock8,514 |
|
19.685" (500mm) | - | - | - | Cable | IEC IP64 | - | Infrared (950nm) | - | -25°C ~ 70°C |
|
|
Omron Automation and Safety |
E32-LD11 WITH 5M CABLE
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: Cable
- Ingress Protection: IEC IP50
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -40°C ~ 70°C
|
Package: - |
Stock4,536 |
|
- | - | - | - | Cable | IEC IP50 | - | - | - | -40°C ~ 70°C |
|
|
Omron Automation and Safety |
5-30MM DIFFUSE D/ON NPN M3 MTG
- Sensing Method: Reflective, Diffuse
- Sensing Distance: 0.197" ~ 1.181" (5mm ~ 30mm) ADJ
- Voltage - Supply: 12 V ~ 24 V
- Response Time: 1ms
- Output Configuration: NPN - Open Collector/Dark-ON
- Connection Method: Wire
- Ingress Protection: IEC IP67
- Cable Length: -
- Light Source: Infrared (650nm)
- Adjustment Type: -
- Operating Temperature: -25°C ~ 55°C
|
Package: - |
Stock6,696 |
|
0.197" ~ 1.181" (5mm ~ 30mm) ADJ | 12 V ~ 24 V | 1ms | NPN - Open Collector/Dark-ON | Wire | IEC IP67 | - | Infrared (650nm) | - | -25°C ~ 55°C |