|
|
Omron Automation and Safety |
SPARE RECEIVER
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock4,446 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock5,292 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock7,074 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock3,960 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SENSOR PHOTOELECTRIC 2M
- Sensing Method: Through-Beam
- Sensing Distance: 2362.2" (60m) 196.85'
- Voltage - Supply: 12 V ~ 24 V
- Response Time: 1ms
- Output Configuration: NPN - Dark-ON/Light-ON - Selectable
- Connection Method: Cable
- Ingress Protection: IEC IP67
- Cable Length: -
- Light Source: Red (655nm)
- Adjustment Type: Single-Turn
- Operating Temperature: -25°C ~ 55°C
|
Package: - |
Stock3,472 |
|
2362.2" (60m) 196.85' | 12 V ~ 24 V | 1ms | NPN - Dark-ON/Light-ON - Selectable | Cable | IEC IP67 | - | Red (655nm) | Single-Turn | -25°C ~ 55°C |
|
|
Omron Automation and Safety |
SENS OPTO REFL 50MM PREWIRED MOD
- Sensing Method: Reflective, Diffuse
- Sensing Distance: 1.969" (50mm)
- Voltage - Supply: 12 V ~ 24 V
- Response Time: 1ms
- Output Configuration: PNP - Dark-ON/Light-ON - Selectable
- Connection Method: Wire
- Ingress Protection: IEC IP67
- Cable Length: -
- Light Source: Red (680nm)
- Adjustment Type: Single-Turn
- Operating Temperature: -25°C ~ 55°C
|
Package: - |
Stock3,726 |
|
1.969" (50mm) | 12 V ~ 24 V | 1ms | PNP - Dark-ON/Light-ON - Selectable | Wire | IEC IP67 | - | Red (680nm) | Single-Turn | -25°C ~ 55°C |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock2,160 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock8,748 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock3,276 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock5,364 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: Through-Beam
- Sensing Distance: 787.4" (20m)
- Voltage - Supply: 24V
- Response Time: 14ms
- Output Configuration: PNP - Open Collector
- Connection Method: Cable with Connector
- Ingress Protection: IP65
- Cable Length: -
- Light Source: Infrared (880nm)
- Adjustment Type: -
- Operating Temperature: -10°C ~ 55°C
|
Package: - |
Stock5,094 |
|
787.4" (20m) | 24V | 14ms | PNP - Open Collector | Cable with Connector | IP65 | - | Infrared (880nm) | - | -10°C ~ 55°C |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock3,132 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: Through-Beam
- Sensing Distance: 787.4" (20m)
- Voltage - Supply: 24V
- Response Time: 14ms
- Output Configuration: PNP - Open Collector
- Connection Method: Cable with Connector
- Ingress Protection: IP65
- Cable Length: -
- Light Source: Infrared (880nm)
- Adjustment Type: -
- Operating Temperature: -10°C ~ 55°C
|
Package: - |
Stock5,346 |
|
787.4" (20m) | 24V | 14ms | PNP - Open Collector | Cable with Connector | IP65 | - | Infrared (880nm) | - | -10°C ~ 55°C |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock2,754 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: Through-Beam
- Sensing Distance: 787.4" (20m)
- Voltage - Supply: 24V
- Response Time: 14ms
- Output Configuration: PNP - Open Collector
- Connection Method: Cable with Connector
- Ingress Protection: IP65
- Cable Length: -
- Light Source: Infrared (880nm)
- Adjustment Type: -
- Operating Temperature: -10°C ~ 55°C
|
Package: - |
Stock7,380 |
|
787.4" (20m) | 24V | 14ms | PNP - Open Collector | Cable with Connector | IP65 | - | Infrared (880nm) | - | -10°C ~ 55°C |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock6,534 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: Through-Beam
- Sensing Distance: 787.4" (20m)
- Voltage - Supply: 24V
- Response Time: 14ms
- Output Configuration: PNP - Open Collector
- Connection Method: Cable with Connector
- Ingress Protection: IP65
- Cable Length: -
- Light Source: Infrared (880nm)
- Adjustment Type: -
- Operating Temperature: -10°C ~ 55°C
|
Package: - |
Stock3,580 |
|
787.4" (20m) | 24V | 14ms | PNP - Open Collector | Cable with Connector | IP65 | - | Infrared (880nm) | - | -10°C ~ 55°C |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock2,826 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
TRANSMITTER SAFETY LIGHT CURTAIN
- Sensing Method: Through-Beam
- Sensing Distance: 787.4" (20m)
- Voltage - Supply: 24V
- Response Time: 14ms
- Output Configuration: PNP - Open Collector
- Connection Method: Cable with Connector
- Ingress Protection: IP65
- Cable Length: -
- Light Source: Infrared (880nm)
- Adjustment Type: -
- Operating Temperature: -10°C ~ 55°C
|
Package: - |
Stock4,770 |
|
787.4" (20m) | 24V | 14ms | PNP - Open Collector | Cable with Connector | IP65 | - | Infrared (880nm) | - | -10°C ~ 55°C |
|
|
Omron Automation and Safety |
SYSTEM
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock8,262 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SAFETY LIGHT CURTAIN
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock2,520 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SPARE RECEIVER
- Sensing Method: -
- Sensing Distance: -
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: -
- Ingress Protection: -
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -
|
Package: - |
Stock3,402 |
|
- | - | - | - | - | - | - | - | - | - |
|
|
Omron Automation and Safety |
SENS HIGH FLEX T-BEAM 3MM DIA
- Sensing Method: Through-Beam
- Sensing Distance: 20.866" (530mm)
- Voltage - Supply: -
- Response Time: -
- Output Configuration: -
- Connection Method: Cable
- Ingress Protection: IP67
- Cable Length: -
- Light Source: -
- Adjustment Type: -
- Operating Temperature: -40°C ~ 70°C
|
Package: - |
Stock7,488 |
|
20.866" (530mm) | - | - | - | Cable | IP67 | - | - | - | -40°C ~ 70°C |
|
|
Omron Automation and Safety |
SENS OPTO REFL 100MM-2M PREWIRED
- Sensing Method: Retroreflective, Polarized
- Sensing Distance: 3.937" ~ 78.740" (100mm ~ 2m) ADJ
- Voltage - Supply: 10 V ~ 30 V
- Response Time: 2.5ms
- Output Configuration: PNP - Dark-ON/Light-ON - Selectable
- Connection Method: Wire
- Ingress Protection: NEMA 6
- Cable Length: -
- Light Source: Infrared (660nm)
- Adjustment Type: Fixed
- Operating Temperature: -25°C ~ 55°C
|
Package: - |
Stock3,384 |
|
3.937" ~ 78.740" (100mm ~ 2m) ADJ | 10 V ~ 30 V | 2.5ms | PNP - Dark-ON/Light-ON - Selectable | Wire | NEMA 6 | - | Infrared (660nm) | Fixed | -25°C ~ 55°C |
|
|
Omron Automation and Safety |
SENSOR PHOTOELECTRIC 1M
- Sensing Method: Reflective, Diffuse
- Sensing Distance: 39.370" (1m)
- Voltage - Supply: 12 V ~ 24 V
- Response Time: 1ms
- Output Configuration: NPN - Dark-ON/Light-ON - Selectable
- Connection Method: Cable
- Ingress Protection: IEC IP67
- Cable Length: -
- Light Source: Infrared (860nm)
- Adjustment Type: Single-Turn
- Operating Temperature: -25°C ~ 55°C
|
Package: - |
Stock5,562 |
|
39.370" (1m) | 12 V ~ 24 V | 1ms | NPN - Dark-ON/Light-ON - Selectable | Cable | IEC IP67 | - | Infrared (860nm) | Single-Turn | -25°C ~ 55°C |
|
|
Omron Automation and Safety |
SENS OPTO REFL 100MM-2M PREWIRED
- Sensing Method: Retroreflective, Polarized
- Sensing Distance: 3.937" ~ 78.740" (100mm ~ 2m) ADJ
- Voltage - Supply: 10 V ~ 30 V
- Response Time: 2.5ms
- Output Configuration: PNP - Dark-ON/Light-ON - Selectable
- Connection Method: Wire
- Ingress Protection: NEMA 6
- Cable Length: -
- Light Source: Infrared (660nm)
- Adjustment Type: Fixed
- Operating Temperature: -25°C ~ 55°C
|
Package: - |
Stock7,704 |
|
3.937" ~ 78.740" (100mm ~ 2m) ADJ | 10 V ~ 30 V | 2.5ms | PNP - Dark-ON/Light-ON - Selectable | Wire | NEMA 6 | - | Infrared (660nm) | Fixed | -25°C ~ 55°C |
|
|
Panasonic Industrial Automation Sales |
SENSOR PHOTO PNP 100MM 12-24V
- Sensing Method: Reflective, Diffuse
- Sensing Distance: 3.937" (100mm)
- Voltage - Supply: 12 V ~ 24 V
- Response Time: 1ms
- Output Configuration: PNP - Open Collector
- Connection Method: Connector, M12
- Ingress Protection: IP67
- Cable Length: -
- Light Source: Infrared
- Adjustment Type: -
- Operating Temperature: -25°C ~ 55°C
|
Package: - |
Stock6,012 |
|
3.937" (100mm) | 12 V ~ 24 V | 1ms | PNP - Open Collector | Connector, M12 | IP67 | - | Infrared | - | -25°C ~ 55°C |
|
|
Panasonic Industrial Automation Sales |
SENSOR LASER 5MM WIDE 500MM
- Sensing Method: Reflective, Diffuse
- Sensing Distance: 19.685" (500mm)
- Voltage - Supply: -
- Response Time: -
- Output Configuration: Analog
- Connection Method: Cable
- Ingress Protection: -
- Cable Length: 19.5" (50cm)
- Light Source: Green LED
- Adjustment Type: Adjustable
- Operating Temperature: 0°C ~ 50°C
|
Package: - |
Stock7,128 |
|
19.685" (500mm) | - | - | Analog | Cable | - | 19.5" (50cm) | Green LED | Adjustable | 0°C ~ 50°C |